13.2Instrumenttroubleshooting
ProblemAppliestoExamplescreenshotsAction
Lowbattery.i40Bidata
i40Depth
i40Speed
i40Wind
D12 5 21-1
Rechargeyourvessel's
batteryassoonaspossible.
Blankdisplay.i40Bidata
i40Depth
i40Speed
i40Wind
D12 5 22-1
Checkfuse/circuitbreaker.
Checkpowersupply.
CheckSeaTalkcablingand
connectorsecurity.
Depthreadingasheswhen
underway.
i40Bidata
i40Depth
D12 5 23-1
Ensurethereading
stabilizeswhenclear
ofdisturbedwater(e.g.
vesselwakes,propeller
washetc.).
Nodata.i40Bidata
i40Depth
i40Speed
i40Wind
D12 5 24-1
Checktheconditionof
thetransducercableand
securityoftheconnections.
Checkconditionof
transducerfaceandremove
anydebris.
Fori40windiftrue
windspeedinformation
ismissingbutapparent
windispresentthenthis
couldbeduetonospeed
informationviaSeaTalk.