Chapter 4: Fault-finding & Maintenance 25
4 Fault-finding & Maintenance
Chapter 4: Fault-finding & Maintenance
All Raymarine products are designed to provide many years of
trouble-free operation. We also put them through comprehensive
testing and quality assurance procedures before shipping.
Regular checks
CAUTION:
The GyroPlus 2 unit and fluxgate compass do NOT contain user-
serviceable parts. They should be serviced only by authorized
Raymarine service technicians.
On a regular basis:
check that all connections and mountings are secure/undamaged
check the system components for any signs of physical damage or
water damage
Note: Do not use chemical or abrasive materials to clean the
GyroPlus 2 unit cover or fluxgate compass case. If they are dirty,
wipe them with a clean, damp cloth.
Fault-finding
Status LEDs
The GyroPlus 2 unit has two status LEDs just above the Rate outputs.
These light-up during normal operation and flash to indicate compass/
gyro faults:
Normal operation
On power-up Both LEDs on for 3 sec
Turn to port Red LED on whilst turning
Turn to starboard Green LED on whilst turning
Stationary Both LEDs off
Fault-finding
Red LED flashing Compass fault - check connections
Green LED flashing GyroPlus 2 unit fault - contact Raymarine Technical Services
81198_1.book Page 25 Monday, February 11, 2002 8:36 AM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine Pathfinder GyroPlus 2 and is the answer not in the manual?

Raymarine Pathfinder GyroPlus 2 Specifications

General IconGeneral
BrandRaymarine
ModelPathfinder GyroPlus 2
CategoryAutopilot System
LanguageEnglish

Related product manuals