EasyManua.ls Logo

Raymarine RAY91 - Chapter 3 Installation Guide

Raymarine RAY91
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ConnectionConnectsto
Suitable
cables
5
HS1(Handset
station1)
connection
R
aymic
handsetor
Adaptorcable
Raymic
handset’s
fittedcable.
6HS2
(Handset
station2)
connection
R
aymic
handsetor
Adaptorcable
Raymic
handset’s
fittedcable.
7Hub
connection
DONO
T
CONNECT
8
N2K(NMEA
2000)
connection
Sea
Talkng®/
NMEA2000
backbone
Thesupplied
DeviceNetto
SeaT alkng®
adaptor
cableora
DeviceNet
spurcable.
Bareendwireconnections
Y
ourproductissuppliedwithbareendwireconnections.
Y oumustensurethatALLbareendwiresareadequately
protectedfromshortcircuitandwateringress.
Bareendedwireconnections
Itisrecommendedthatbareendedwireconnectionsare
madebysolderingorusingcrimpconnectorsandthen
protectedbywrappingtheconnectionininsulationtape.
Unusedbareendedwires
Anyunusedbareendedwiresshouldbefoldedback
andwrappedininsulationtape.
4.3Powerconnection
Thepowersupplyshouldbeconnectedasshownbelow:
1.Basestation
2.P
owersupplypositive(+)Redwire
3.Powersupplynegative(-)Blackwire
4.Suitablewaterproofconnection(Basestationis
suppliedwithbulletcrimpsonpowersupplywires.)
5.12Vdcpowersource
W
arning:12Voltdconly
Thisproductmustonlybeconnectedtoa
12voltdcpowersource
.
W
arning:Positiveground
systems
Donotconnectthisunittoasystemwhich
haspositivegrounding.
In-linefuseandthermalbreak
er
ratings
Thefollowingin-linefuseandthermalbreakerratings
applytoyourproduct:
In-linefuseratingThermalbreak
errating
10A
7A(ifonlyconnecting
onedevice)
Note:
Thesuitablefuseratingforthethermalbreak
er
isdependentonthenumberofdevicesyouare
connecting.Ifindoubtconsultanauthorized
Raymarine
®
dealer.
Y ourproduct’spowercablemayhavefittedin-line
fuse,ifnotthenyoucanaddanin-linefusetothe
positivewireofyourproductspowerconnection.
Grounding
Thisproductisgroundedthroughthe0Vdcnegative
wireonthepowercableanddoesnotrequireadrain
(shield)tobeconnectedtothebasestation’sground
terminal.
Powerdistribution
Recommendationsandbestpractice.
Theproductissuppliedwithapowercable,either
asaseparateitemoracaptivecablepermanently
attachedtotheproduct.Onlyusethepowercable
suppliedwiththeproduct.DoNOTuseapowercable
designedfor,orsuppliedwith,adifferentproduct.
Refertothe
Powerconnection
sectionformore
informationonhowtoidentifythewiresinyour
product’
spowercable,andwheretoconnectthem.
Seebelowformoreinformationonimplementationfor
somecommonpowerdistributionscenarios.
Cablesandconnections
27
81377-1-en_US_PRINT.pdf 27 12/21/2017 9:05:37 PM

Table of Contents

Other manuals for Raymarine RAY91

Related product manuals