8
HIGH WIND LOAD RESTRAINT DETAIL 1
PAD SPECIFICATION:
GREATER THAN OR EQUAL TO 4" THICK SOLID CONCRETE 2000 P. S. I. OR GREATER LOAD RATING
PAD LENGTH GREATER THAN OR EQUAL TO 42.5" (108 cm)
PAD WIDTH GREATER THAN OR EQUAL TO 42.5" (108 cm)
MINIMUM 16 GA. X 3.75” WIDE STAINLESS STEEL
TIE DOWN (MIN. QTY. OF 4 TIE DOWNS) WITH (3)
1/2” LONG #12 SELF DRILLING SCREWS EACH
STRAP (MIN. 1000 HR. COATING)
(2) 1/4” CONCRETE SCREWS
LENGTH TO PENETRATE
2-3/8" (6 cm) MINIMUM.
CONCRETE PAD
(SEE PAD SPECS.)
UNIT
SEE HIGH WIND LOAD
RESTRAINT DETAIL 1
RESTRAINT
SET AT EACH
CORNER
3" MIN. (7.6 cm)
SPACING TYP.
COVERED UNIT
HEIGHT BETWEEN
37-1/2" - 42-13/32" (95-107.7 cm)
WITH PLASTIC
BASE PAN
THIS DRAWING USED AS A GRAPHICAL REPRESENTATION ONLY
AND IT MAY NOT APPEAR EXACTLY LIKE YOUR SPECIFIC UNIT.
THIS DRAWING INTENDED FOR POOL HEATERS ONLY!
QT Model Hurricane Tie Down Specications
Figure 3. QT Model Hurricane Tie Down Specications
5. ELECTRICAL
CONNECTIONS
pages
19 through 23
NOTE: Refer to the National Electrical Code, Article
680, for general requirements for swimming pools and
equipment, and to Article 440 for special considerations
necessary for circuits supplying hermetic refrigeration
motor/compressors.
page24