WorkHorse Sentinel User's Guide
page 10 RD Instruments
Place a light amount of DC-111 lubricant on the end-cap
connector pins (rubber portion only). This will make it eas-
ier to connect or remove the I/O cable and dummy plug.
Do not connect or disconnect the I/O cable with power ap-
plied. An exception to this is the external battery case. The
external battery case connector is always “hot” when batter-
ies are installed. When you connect the cable with power
applied, you may see a small spark. The connector pins
may become pitted and worn.
The WorkHorse I/O cable is wet mate-able, not under water
mate-able.
4.3 Deployment Guidelines
Align the compass whenever the battery pack or recorder
module is replaced, or when any ferrous metals are relocated
inside or around the WorkHorse housing. Ferro-magnetic
materials affect the compass.
The AC power adapter is not designed to withstand water.
Use caution when using on decks in wet conditions.
Avoid using ferro-magnetic materials in the mounting
fixtures or near the Workhorse. Ferro-magnetic materials
affect the compass.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RD Instruments WorkHorse Sentinel and is the answer not in the manual?

RD Instruments WorkHorse Sentinel Specifications

General IconGeneral
BrandRD Instruments
ModelWorkHorse Sentinel
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals