EasyManua.ls Logo

RDS PS 8000 - Field Data Logging

Default Icon
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 - Logging Options
3.4 Field Data Logging
For farm record keeping and traceability purposes, you can record a summary of
each job or work session in the internal memory, and subsequently downloaddirectly
to a PC, or print to an RDS ICP200 In-Cab Printer. You can store up to 75 job
summaries.
3.4.1 Start recording Field Data
1 Press the LOG key.
The screen will display the current logging status, the number of jobs (job
summaries) stored in memory, and the status of the PCMCIA card if found (fig. 10a).
2 Press the START key. The JOB STARTUPpage is displayed (fig.17)
3 Select the logging option "LOG SUMMARY ONLY".
4 When prompted, enter the FARM NUMBER and FIELD NUMBER reference. The
"EXTENDED DATA FUNCTIONS" page is then displayed. If you don't wish to
programme any extended functions. then press . .
5 If you want to programme extended functions, refer to section 3.2.5.
The "RECORDING A JOB SUMMARY" page appears (fig. 25). While field data
logging is in progress, the icon appears animated at the top of the screen.
NOTE: If more than one machine is enabled, the summary job record will include data for
each machine.
3.4.2 Stop recording Field Data
To stop running a job, simply press the "STOP" key on the LOG screen. The job
summary is saved to the internal memory.
Figure 25
Field Data Logging
28

Related product manuals