B.7 Power Status and overload (IEEE 802.3bt, single signature)
RT-PoE commands:
PSE check after commands issued
reset
detect ok
single on
class 8
set 20
connect on
Enable power to port
Verify that PSE sees the device is taking power.
status
Verify that power is on.
getv
Verify that voltages are as expected.
set 1426
Verify that PSE is providing full power.
set 2000
Verify that PSE sees overload and shuts off
power.
status
Verify that power is off.
B.8 Power Status and overload (IEEE 802.3bt, dual signature)
RT-PoE commands:
PSE check after commands issued
reset
detect ok
single off
class 5
set 20
connect on
Enable power to port
Verify that PSE sees the device is taking power.
status
Verify that power is on.
getv
Verify that voltages are as expected.
set 1426
Verify that PSE is providing full power.
set 2000
Verify that PSE sees overload and shuts off
power.
status
Verify that power is off.