Maintenance
30 Owner’s Guide – Redback Smart Hybrid System – v3.8
Maintenance
13.1 Schedule
WARNING: ELECTROCUTION HAZARD. Lethal voltages may be present. Isolate all sources of power and test
before removing covers.
Your Redback SH5000 is a low maintenance product. You can undertake the minor annual maintenance identified below.
Internal maintenance must be conducted by a qualified person, such as your installer.
Note: Filters, fans and heatsink fins may require more frequent cleaning in dusty conditions.
Enclosure
vents, filters,
and fan blades.
Airflow is reduced when dust
accumulates on the vents or the
filter is clogged.
The lower intake vents are more
Cabinet may become soiled.
Wipe down outside of cabinet with a
just-damp cloth. Immediately wipe
dry with a microfibre cloth.
Do not use cleaning agents as they
heatsink fins
Cooling efficiency reduces when
dust, dirt or debris accumulate on
Clean the heatsink fins using a small
brush, cloth or compressed air.
connections
Battery efficiency may reduce if
connections or terminals become
Unplug and inspect battery cable
connections. Remove corrosion or
debris. Spray with contact cleaner.
Concealed seals ensure cabinet
water resistance.
Remove covers and inspect seals for
hardening, tears or other damage.
Look for signs of water in cabinets.
Cable seals prevent water and
insects entering the inverter.
Remove BoS Front Cover and tighten
all cable glands and waterproof caps.