SELECTION OF THE MAXIMUM DURATION AND TYPE OF MUTING
The inputs of the JANUS light curtain receiver make it possible to configure the various types of
Muting available and the maximum duration of the Muting condition (timeout).
At power-on, for correct functioning, the various inputs must be connected as indicated below.
Model
Receiver pin
Timeout
selected
10 (CONF3)
9 (CONF2)
"MT"
0
24VDC
t1
24VDC
0
t2
"ML"
"ML S2"
0
24VDC
t1
24VDC
0
t2
Table 12 - Models with 2 sensors
where: t1 = 30 sec; t2 = 90 min
NOTE: For the MT (with 2 sensors) and ML models, pin 7 and 8 must not be connected.
Model
Receiver pin
Timeout
selected
MEANING
10 (CONF3)
9 (CONF2)
8 (CONF1)
7 (CONF0)
"MI"
(2 sensors)
0
24VDC
0
0
t1
Concurrent mode
(within 4sec)
24VDC
0
0
0
t2
"MI" with
“L” logic
0
24VDC
24VDC
24VDC
t1
24VDC
0
24VDC
24VDC
t2
"MI"
(4 sensors)
"MT S4"
0
0
0
24VDC
t1
Concurrent mode
(within 4sec)
0
0
24VDC
0
infinite
24VDC
24VDC
0
24VDC
t1
Sequential mode
24VDC
24VDC
24VDC
0
infinite
Table 13 - Models MI and models MT with 4 sensors
where: t1 = 30 sec; t2 = 90 min
OVERRIDE CONFIGURATION
Receiver pin
MEANING
16 (OVERRIDE1)
17 (OVERRIDE2)
0
0
Selection override with spring return key
0
24VDC
Selection override with push button (switch)
24VDC
0
Not permitted
24VDC
24VDC
Not permitted