37 H0F.01 × 0 × Rotation direction of external encoder 0 forward and 1 reverse
38 H0F.04 × 1000 ×
The number of pulses of the external encoder when the motor
rotates one circle
39 H0F.08 × 100 × External encoder pulse deviation threshold
40 H0F.10 × 1 × Closed loop deviation clearing setting
2) Drive parameter:
There are 23 non-resettable faults in total.
Fault name The cause of the failure and its treatment Remark
ER101, system parameter
is abnormal
The function code parameter stored in EEPROM exceeds
the setting range of the function code.
The fault
cannot be reset,
and the problem
may occur after
the software is
upgraded and
burned.
ER102, logic
configuration failure
Reason (1): After the driver downloads the new version
of the software, the function code setting range of the new
version of the software does not match the old function code.
Non-resettable
fault, this problem
generally does not
appear in official
products.
ER105, system parameter
is abnormal
Processing method: Enter the function code H0231,
input 1 (system parameter initialization), the drive is
powered on again or the drive software is reset.
Non-resettable
fault, this problem
generally does not
appear in official
products.
ER107, no corresponding
motor or driver
Reason (2): Due to software design, the default
parameters of the function code are not within the setting
range of the function code.
Non-resettable
fault
ER108, parameter storage
failure
Processing method: The upper computer software reads
the function code setting parameters, and checks whether
each function code parameter is within the upper and lower
limits set by the function code. Find the function code whose
parameter setting is not in the range, modify it so that the
parameter setting is within the upper and lower limits, and
then re-power on or reset by software.
Non-resettable
fault
ER110, frequency
division pulse output setting
failure
The FPGA function defined in the FPGA register does
not match the FPGA function defined in the DSP register.
Non-resettable
fault
ER120, product matching
failure
Reason (1): Due to the unreasonable design of the
software interface, the FPGA function defined in the FPGA
register does not match the FPGA function defined in the
DSP register.
Non-resettable
fault
ER135, EEPROM error in Treatment method: software design problem, re-upgrade Non-resettable