fault 2 exceeds the resolution range of the encoder. fault
ER 833, current sampling
fault 1
Reason (1): The frequency division output function code
parameter exceeds the encoder resolution range. For
example, a 1000-line photoelectric encoder can output 1000
pulses at the highest frequency division. If the frequency
division output is set to output 1001 pulses, the fault will be
reported.
Non-resettable
fault
Type 1 resettable faults, a total of 12 faults.
ER104, parameter
combination failure
Type 1
resettable fault,
unused fault
ER121, servo ON
command invalid fault
When the servo drive is enabled, an illegal servo
auxiliary function operation is executed.
Type 1
resettable fault
ER130, DI allocation
failure
Reason (1): Under the condition that the servo drive is
enabled, some servo auxiliary function operations that need
to be stopped can be executed.
Type 1
resettable fault
ER131, DO allocation
failure
Solution: Reset the fault through the reset switch signal
(AlmRst).
Type 1
resettable fault
ER140, AI selection
failure
An error occurs when the DI physical terminal
distributes the DI signal and the fault is reported.
Type 1
resettable fault
ER 152, multi-speed
execution time is too short
Reason (1): Two DI physical terminals are assigned the
same DI signal. For example, DI5 is assigned as Son signal
by default (function code H0310 is set to 1), if DI4 is also
assigned as Son signal (function code H0308 is set to bit 1).
Two different physical terminals (DI4, DI5) are assigned the
same DI signal (Son signal), and the fault is reported.
Type 1
resettable fault ,
unused fault
ER160, PID controller
output distribution failure
Solution: Check the DI signal distribution function code
to ensure that there is no duplication of DI signal
distribution.
Type 1
resettable fault
ER400, busbar
overvoltage
Reason (2): The DI physical terminal is assigned a signal
that exceeds the maximum range of the DI signal. The
current maximum range of DI signal is 32. If the DI physical
terminal allocation exceeds this range, the system will report
the fault. (Normally, this will not happen)
ER500, the feedback
speed is overspeed
Solution: driver program design problem, upgrade driver
program.
Type 1
resettable fault
ER501, position
command overspeed
When the DO physical terminal distributes the DO
signal, an error occurs and the fault is reported.
Type 1
resettable fault,
unused fault
ER510, frequency
division pulse output is too
fast
Reason (1): Two DO physical terminals are assigned the
same DO signal. For example, DO1 is allocated as SRdy
signal by default (function code H0400 is set to 1), if DO2 is
also allocated as SRdy signal (function code H0402 is set to
Type 1
resettable fault
OperationManualReflexFastFormGX616CNCRebarStirrupBendingMachine