Equipment Operation
6-69
To Fill Fresh Water System:
1. Unscrew the “water” ll deck tting. Fill the fresh water tank with
fresh water with a suitable container or hose. Make sure the water is
safe for drinking.
2. Find the fresh water pump switch/breaker located on the 12 volt
head panel and pull the switch out to engage it. You will hear the
pressurized water pump ll the entire fresh water system. When full
the pump pressure switch will stop the pressure pump.
3. Open the head faucet to allow any air to escape. Close the faucet
when there is a steady stream of water without air. You will hear the
fresh water pressure switch shut off indicating the system is full.
4. After these initial procedures, “top” the system off with fresh
water.
5. Check for system leaks as evidenced by the pressure water pump
recycling even though no water is being used from the components.
6. It is a good idea to turn “off ” the fresh water pump switch after
each use and especially during extended times of non-use.
7. Clean the pressure water lter periodically by disassembling the
lter element and rinsing in fresh water. Ensure the pump switch is
off. Replace and check for leaks. For parts, contact an authorized Regal
dealer.
CAUTION
!
AVOID PRESSURE PUMP BURN OUT!
DO NOT ACTIVATE THE FRESH WATER
SYSTEM WITH THE WATER TANK EMPTY.