Regulus SRS 3 - D 5.18 - Hydraulic Variant Settings Table

Regulus SRS 3
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
R
EGULUS - SRS 3 Controller - www.re
g
ulus
.
eu
Hydraulic variant No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Tmin S1
S1
=>R1+R2
S1 =>R1 S1 =>R1 S1 =>R1 S1 =>R1 S1 =>R2 S1 =>R1 S1 =>R1 S1 =>R1
S1
=>R1+R2
S1 =>R1 S1 =>R1 S1 =>R1 S1 =>R1 S1 =>R1 S1 =>R1 S1 =>R1 S1 =>R1 S1 =>R1 S1 =>R1
Tmin S2 S2 =>R2 S2 =>R2 S2 =>R2
Tmin S3
S3
=>R1+R2
S3 =>R2 S3=>R2
Tmax S2
S2
=>R1+R2
S2 =>R1
S2
=>R1+R2
S2 =>R1 S2 =>R1
S2
=>R1+R2
S2
=>R1+R2
S2
=>R1+R2
S2 =>R1 S2 =>R1 S2 =>R1
S2
=>R1+R2
S2 =>R1 S2=>R1 S2=>R1 S2=>R1
S2=>R1+R2
S2=>R1 S2 =>R1 S2 =>R1
Tmax S3 S3 =>R2
S3
=>R1+R2
S3
=>R1+R2
S3 =>R2 S3 =>R2
S3
=>R1+R2
S3 =>R2
Δ T R1
S1/ S2
=>R1+R2
S1/ S2
=>R1
S1/ S2
=>R1 S3/
S2 =>R2
S1/ S2
=>R1
S1/ S2
=>R1
S1/ S3
=>R1+R2
S1/ S2
=>R2
S3>S2
=>R1
S1/ S2
=>R1
S3/ S2
=>R1+R2
S1/ S2
=>R1
S1/ S2
=>R1
S1/ S3
=>R1+R2
S1/ S2
=>R1
S1/ S2
=>R1
S1/ S2
=>R1 S3/
S2 =>R2
S1/ S2
=>R1
S1/ S3
=>R1+R2
S1/
S2=>R1
S1/
S2=>R1
S1/
S2=>R1
S1/
S2=>R1
S1/
S2=>R1
S1/ S2
=>R1
S1/ S2
=>R1
Δ T R2
S2/ S3
=>R2
S3/ S2
=>R2
S1/ S3
=>R2
S2/ S3
=>R2
S3/
S2=>R2
S2/ S3
=>R2
Tset S3 S3 =>R2 S3=>R2 S3=>R2 S3 =>R2
Hysteresis S3 =>R2 S3=>R2 S3=>R2 S3 =>R2
Priority
S2 or S3
=>R1/ R2
S2 or S3
=>R1/ R2
S2 or S3
=>R1/ R2
S2 or S3
=>R1/ R2
Tpriority
S2 or S3
=>R1/ R2
S2 or S3
=>R1/ R2
S2 or S3
=>R1/ R2
S2 or S3
=>R1/ R2
Settings menu 5
D 5.18 - Table: Programs (hydraulic variants) with associated settings for Regulus SRS3 Controller:
The table lists the settings corresponding to the specic programs (hydraulic variants). The reference sensors are labeled S1, S2, S3. The relays are labeled R1. R2.
Select a column with the desired hydraulic variant. All the condition listed in that column must be fullled for the relay to switch.
Example: Hydraulic variant No. 5. The following conditions must be fullled at the same time for R1 relay to switch: Tmin S1, Tmax S2, Tmax S3, ΔT R1, conditions Priority, Tpriority