E - Defects and Maintenance
E 1 - Error and info messages
If the controller detects a malfunction, the red light
ashes and the warning symbol also appears in the
display. If the error is no longer present, the warning
symbol changes to an info symbol and the red light no
longer ashes.
To obtain more detailed information on the error,
press the key under the warning or info symbol.
Do not try to deal with this yourself. Consult
a specialist in the event of an error!
Possible error messages: Notes for the specialist:
Sensor x defective Means that either the sensor, the sensor input at the controller or the
connecting cable is/was defective. (Resistance table see chap. A6)
Collector alarm Means that the collector has risen/rose above the temperature set
under menu 6.3.1 (chap. 6.3)
Night circulation Means that the solar pump is/was in operation between 23:00 and
04:00. (Exception see D 6.4)
Restart Means that the controller was restarted, for example due to a power
failure. Check the date&time!
Time&date This message appears automatically after a mains failure because
the time&date have to be checked, and reset if necessary.
(LED flashes +
warning symbol)