Implementing pipe cleaning openings
➜ Install a branch instead of a 45° bend at
redirection points.
➜ Provide additional outlet with a dummy
plug (see Fig. 5-18).
➜ Remove dummy plug for cleaning.
Fig. 5-18: Cleaning opening
Connecting central vacuum unit to
vacuum pipes
➜ Connect vacuum pipes to the central
vacuum unit with RAUPIANO Plus double
sleeve.
Securing vacuum pipes
Recommended spacing of pipe brackets:
■ for horizontal pipes: up to 0.5 m
■ for vertical pipes: up to 1.0 m
➜ Secure vacuum pipes with fixed brackets
or guide brackets mounted to the wall with
hanger bolts and plastic plugs.
➜ Attach fixed brackets directly after the
sleeve.
➜ For lengths of 1 m or longer, use guide
brackets as well.
5.6
Central vacuum unit
The central vacuum unit may be installed in a
basement, storage room, utility room or
garage. The site selected should ensure that
vacuum and exhaust air pipes can be kept as
short as possible.
Demands on the site of installation:
■ Lowest room in the entire system
■ Room temperature between 5 °C and
25 °C all year round
■ Ventilate room well, ventilation aperture to
the outside at least 150 cm
2
■ Mains power connection
■ Sufficient space for emptying collected dirt
and servicing work
Observe the following when installing the
radio receiver unit:
➜ Allow a distance of at least 2 m between
central vacuum unit and radio receiver unit.
➜ Do not install central vacuum unit and
radio receiver unit behind steel doors.
If this cannot be avoided, the radio receiver
unit must be installed at a site with
favourable reception outside the room with
the steel door.
➜ Do not install radio receiver unit in the fuse
box or in the vicinity of other wireless
control units.
Mounting central vacuum unit
Fig. 5-19: Mounting wall mount
➜ Fit vibration dampers (2) in the wall mount
(1).
➜ Fix wall mount (1) to the wall at a height of
approx. 1.6 m using screws (3), washers
(4) and wall plugs (5) (see also mounting
instructions (Brochure No. 00F2064).
➜ Using screw and wall plug, fix spacer (6) at
a distance of x below the centre of the wall
mount (1).
➜ Suspend central vacuum unit on wall
mount so that it hangs straight.
Checking the cartridge filter
The central vacuum unit comes pre-fitted
with the cartridge filter.
➜ Check that the cartridge filter is firmly in
place before starting the system.
Warning!
Risk of death!
Ignitable/explosive gasses and mixtures
can cause death, severe burns and
damage to property.
➜ Ensure that no ignitable/explosive
gasses or liquids are found in the room.
➜ Do not install central vacuum unit in
explosion-hazardous areas.
Warning!
Risk of death!
Short circuits at the central vacuum unit
resulting from high humidity can cause
death, severe burns and damage to
property.
➜ Do not install central vacuum unit in
rooms exposed to moisture.
Central vacuum unit
Model
Distance x
2000 and 3000 17 cm
4000 33 cm
Caution!
Damage to property!
Defective cartridge filters can cause
damage to property.
➜ Only operate the system with
undamaged cartridge filter.
➜ Check cartridge filter regularly.
x
1
3
4
2
5
6