Instruction Manual
Radio control devices T3, T5 and T7.
version 1.4 Genn. 10
PROGRAMMING THE RADIO CONTROL
DEVICE
Changing the frequency
The operation of changing frequency is carried out only on the
transmitter, the receiver is tuned automatically.
Release the red Stop/Emergency
mushroom button.
Press the buttons 1 and 7 together and
simultaneously the Start button S, and
release.
The set channel is indicated first with
the tens (number of pulses of the red
Led), then with the units (number of
pulses of the green Led).
Example: channel 23 is displayed with 2
pulses of the red Led and three pulses
of the green Led.
The frequency values are given in the
table on the facing page.
At the end of this sequence the transmitter has entered frequency
changing mode
Each time button 1 is pressed, the CHANNEL function is
obtained (units)
Each time button 2 is pressed, the CHANNEL + function is
obtained (units)
Each time button 3 is pressed, the CHANNEL 10 function is
obtained (tens)
Each time button 4 is pressed, the CHANNEL +10 function is
obtained (tens)
The set channel is indicated first with the tens (number of pulses
of the red Led), then with the units (number of pulses of the
green Led).
Once the desired frequency value has been set, press the red
Stop/Emergency mushroom button and wait at least 3 seconds,
then release it.
Press the START button S for a few seconds and hold it down
until the machine starts.
1
2
3 4
5
6
7
S
RED LED
(TENS)
GREEN LED
(UNITS)
Figure 14
page 20 of 28 REMdevice
®
- ITALY

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REMdevice t3 and is the answer not in the manual?

REMdevice t3 Specifications

Operating Environment IconOperating Environment
operative frequency range 1869.700 – 870.000 MHz
operative frequency range 2433.050 – 434.790 MHz
operating and storage temperature-20°C / +70°C
Power IconPower
power supply option 112-24Vdc 1, 0A
power supply option 224-48Vac/dc 50-60 Hz 0.4A
power supply option 348-115Vac/dc 50-60 Hz 0.4A
power supply option 4115-230Vac/dc 50-60 Hz 0.2A
Receiver Specifications IconReceiver Specifications
command relay contacts capacity4A 115 Vac.
stop relay contacts capacity4A 115 Vac.
range of control100 mt.
Transmitter Specifications IconTransmitter Specifications
radio frequency output power1 to 10 mW
supply voltage3.6 Vdc.
power consumption range13.5 mA to 24 mA
batteryintegrated lithium ions 3.6V
working autonomyup to 1200 hours (20°C)
low battery warningat 30 hours left
Dimensions and Weight IconDimensions and Weight
container dimensions158×90×75 mm (L×H×D)
watertight case Ruby-T7 dimensions169×266×89 mm (L×H×D)
watertight case ECOBOX dimensions124×176×45 mm (L×H×D)
transmitter dimensions176x85x37 mm (L×H×D)
transmitter weight350 g