Page #5 background image
Instruction Manual
Radio control devices T3, T5 and T7.
version 1.4 Genn. 10
Activation
1- Turn and release the Stop/Emergency button (Figure 1): power is
supplied to the transmitter.
2- Press the START button. Activation is indicated by the blinking of
the green led (ON) at intervals of about 1 second. If the transmitter
gives a Beep accompanied by the lighting of the red led, check to
make sure that other buttons have not been pressed. If the receiver
is ready too, you should hear the sound of the obligatory acoustic
warning installed on the operating machine.
Use of the radio control device
Press the control buttons for the desired function, taking care as they
may be of the type with a sequential double click: by increasing the
pressure on the button, a second contact is made that is normally
assigned to increasing the speed of a machine movement.
If any kind of difficulty occurs in controlling the operating machine
(for mechanical or electrical reasons, or at any rate independent of
the intentions of the operator), immediately press the red
Stop/Emergency mushroom button.
The radio control device has an automatic interlock on the controls of
opposite or incompatible functions: for example, Up/Down,
Left/Right, Forward/Back.
Periodically check the efficiency of the red Stop/Emergency
mushroom button.
Switching off
Press the red Stop/Emergency mushroom button.
At the end of the manoeuvres, and anyway before putting the
transmitter away, always switch it off.
Do not leave the transmitter unattended when switched on and
unlocked.
Put the transmitter away in a safe place, inaccessible to unauthorised
persons.
Never entrust the transmitter to unskilled personnel.
REMdevice
®
- ITALY
page 5 of 28

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REMdevice t3 and is the answer not in the manual?

REMdevice t3 Specifications

Operating Environment IconOperating Environment
operative frequency range 1869.700 – 870.000 MHz
operative frequency range 2433.050 – 434.790 MHz
operating and storage temperature-20°C / +70°C
Power IconPower
power supply option 112-24Vdc 1, 0A
power supply option 224-48Vac/dc 50-60 Hz 0.4A
power supply option 348-115Vac/dc 50-60 Hz 0.4A
power supply option 4115-230Vac/dc 50-60 Hz 0.2A
Receiver Specifications IconReceiver Specifications
command relay contacts capacity4A 115 Vac.
stop relay contacts capacity4A 115 Vac.
range of control100 mt.
Transmitter Specifications IconTransmitter Specifications
radio frequency output power1 to 10 mW
supply voltage3.6 Vdc.
power consumption range13.5 mA to 24 mA
batteryintegrated lithium ions 3.6V
working autonomyup to 1200 hours (20°C)
low battery warningat 30 hours left
Dimensions and Weight IconDimensions and Weight
container dimensions158×90×75 mm (L×H×D)
watertight case Ruby-T7 dimensions169×266×89 mm (L×H×D)
watertight case ECOBOX dimensions124×176×45 mm (L×H×D)
transmitter dimensions176x85x37 mm (L×H×D)
transmitter weight350 g

Related product manuals