EasyManua.ls Logo

Renfert Silent TS2 - Start-Up Threshold; Shut-Off Delay

Renfert Silent TS2
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 12 -
Press menu key (30) 3x
Ƈ The dust drawer symbol (33) blinks
Ƈ The set sensitivity level is shown.
&KDQJHWKHOHYHOXVLQJWKHEXWWRQV
Ƈ IXOO
Ƈ ORZ¿OOOHYHO
Press enter button (40).
5.3.4 Start-Up Threshold
The start-up threshold, the point at which the connected electrical appliance opens the suction hose,
can be individually adjusted for each hose.
Press menu key (30) 4x
Ƈ The start-up threshold symbol (34) blinks.
Ƈ The letters A and B blink.
Press the suction hose button (39) of the suction which is to be adjusted
Ƈ The letter of the selected hose is indicated.
Ƈ The display shows „OFF“.
Switch the electrical appliance off. Units equipped with a stand-by mode should be switched to
stand-by (e.g. in the case of a hand piece, only switch the controller on without activating the hand
piece).
Press the enter button (40)
Ƈ The display shows “ON”.
Switch the electrical appliance on, e.g. activate the hand piece at the speed at which you require the
suction hose to open.
Press the enter button (40).
Select the next suction hose which you would like to adjust, or quit this menu by pressing the menu
key (30).
Before selecting a suction hose, press the /
/
/
/
/
buttons together and the start-up threshold on
both hoses will return to the factory set parameter (8 W).
5.3.5 Shut-Off Delay
Shut-off delay = the amount of time between switching the connected electrical appliance off and the
closure of the respective suction hose (= pinch valve).
Two types of shut-off delay times can be distinguished, each of which can be set independently of one
DQRWKHU
 2QO\RQHRIWKHWZRVXFWLRQKRVHV$25%LVRSHQ
Set the time, from when the pinch valve in the suction hose closes and the suction turbine shuts off
(e.g. for targeted suction of residue dust)
MENU
A
B
OFF
ON
B
resetdefault
Fig. 13
30
40
34
39
MENU
A
B
OFF
ON
A
B
resetdefault
Fig. 14
30
40
EN