- 16 -
)DFWRU\VHWSDUDPHWHU
Function / Feature Adjustment Range Factory Parameter
Extraction force, one suction
hose is open
1 - 3 2
Extraction force, both suction
hoses are open
1 - 3 2
6HQVLWLYLW\RIGXVWEDJ¿OOOHYHO
Recognition
1 - 9 5
Diagnosis - mode
(after switching on)
On / Off Off
Audible Signal On / Off Off
Automatic start-up threshold 1- 100 W 8 W
Shut-off delay A or B,
one suction hose is open
3 - 30 Sec. 3 Sec.
Shut-off delay, A/B
both Suction hoses are open
3 - 30 Sec. 15 Sec.
6.6 Spare Parts
For the order numbers of consumables and spare parts please refer to the spare parts list at the end of
this manual.
6HULDOQXPEHUVPDQXIDFWXUHGDWHDQGGHYLFHW\SHFDQEHIRXQGRQWKHGHYLFHLGHQWL¿FDWLRQSODWH
7. Troubleshooting
Error Possible Cause Corrective Action
Extractor stops
suddenly for no
apparent reason and a
error code is indicated
in the display
An error has been detected. See table “Error Codes”
If the instructions are of no help to you, or the error
FRGHLVQRWOLVWHG
- Make a note of the error code.
- Send the device in for repair.
- Inform the repair service which error code was
noted.
Dust bag over full Sensitivity of “dust bag full“ signal is
too large
Set a smaller value (See chapter 5.3.3)
“Dust bag full” indicator
goes on, even though
the bag is not full
Sensitivity of “dust bag full“ signal
is too low
Set a larger value (See chapter 5.3.3)
Suction hose cannot be
closed by pressing the
suction hose button
An electrical appliance which is
connected to the suction hose is
still in operation.
Switch the connected electrical appliance off.
“Dust bag full” indicator
appears shortly after
having replaced the dust
bag
)LQHSDUWLFOH¿OWHULVEORFNHG
Suction hose blocked
Cross-section of the dust
JHQHUDWLQJGHYLFH¶VKRVH¿WWLQJLV
too small.
5HSODFHWKH¿QHSDUWLFOH¿OWHU&KDSWHU
Remove the obstruction in the suction hose
Reset the sensitivity of the “dust bag full” indicator
(Chapter 5.3.3)..
Extractor fails to start
when a dust generating
device is being used.
Extractor is not switched on.
Device fuse has blown.
Dust generating device is not
connected to the extractor socket.
Start-up threshold of the suction
hose is too high.
Switch the extractor on (Chapter 5.1).
Check and reinstall the fuse if necessary (Chapter
6.4).
Connect the dust generating device to the coupler
socket (Chapter 4.7).
Adjust start-up threshold (Chapter 5.3.4)