)DFWRU\VHWSDUDPHWHU
Function / Feature Adjustment Range Factory Parameter
Extraction force, one suction
hose is open
1 - 3 2
Extraction force, both suction
hoses are open
1 - 3 2
6HQVLWLYLW\RIGXVWEDJ¿OOOHYHO
Recognition
1 - 9 5
Diagnosis - mode
(after switching on)
On / Off Off
Audible Signal On / Off Off
Automatic start-up threshold 1- 100 W 8 W
Shut-off delay A or B,
one suction hose is open
3 - 30 Sec. 3 Sec.
Shut-off delay, A/B
both Suction hoses are open
3 - 30 Sec. 15 Sec.
6.6 Spare Parts
For the order numbers of consumables and spare parts please refer to the spare parts list at the end of
this manual.
6HULDOQXPEHUVPDQXIDFWXUHGDWHDQGGHYLFHW\SHFDQEHIRXQGRQWKHGHYLFHLGHQWL¿FDWLRQSODWH
7. Troubleshooting
Error Possible Cause Corrective Action
Extractor stops
suddenly for no
apparent reason and a
error code is indicated
in the display
An error has been detected. See table “Error Codes”
If the instructions are of no help to you, or the error
FRGHLVQRWOLVWHG
- Make a note of the error code.
- Send the device in for repair.
- Inform the repair service which error code was
noted.
Dust bag over full Sensitivity of “dust bag full“ signal is
too large
Set a smaller value (See chapter 5.3.3)
“Dust bag full” indicator
goes on, even though
the bag is not full
Sensitivity of “dust bag full“ signal
is too low
Set a larger value (See chapter 5.3.3)
Suction hose cannot be
closed by pressing the
suction hose button
An electrical appliance which is
connected to the suction hose is
still in operation.
Switch the connected electrical appliance off.
“Dust bag full” indicator
appears shortly after
having replaced the dust
bag
)LQHSDUWLFOH¿OWHULVEORFNHG
Suction hose blocked
Cross-section of the dust
JHQHUDWLQJGHYLFH¶VKRVH¿WWLQJLV
too small.
5HSODFHWKH¿QHSDUWLFOH¿OWHU&KDSWHU
Remove the obstruction in the suction hose
Reset the sensitivity of the “dust bag full” indicator
(Chapter 5.3.3)..
Extractor fails to start
when a dust generating
device is being used.
Extractor is not switched on.
Device fuse has blown.
Dust generating device is not
connected to the extractor socket.
Start-up threshold of the suction
hose is too high.
Switch the extractor on (Chapter 5.1).
Check and reinstall the fuse if necessary (Chapter
6.4).
Connect the dust generating device to the coupler
socket (Chapter 4.7).
Adjust start-up threshold (Chapter 5.3.4)
EN