- 18 -
Error Code Cause / Meaning Corrective Action
Err22 Suction hose A blocked or defect. Make sure the suction line and pinch valve in the
suction hose are not blocked.
Err23 Suction hose B blocked or defect.
Err26 Suction hose A or B permanently open. Make sure the pinch valve on the suction hose is not
blocked that the pinch valve membrane is not defect.
Check to ensure that the pinch valve is assembled
correctly.
Err51 Error occurred whilst adjusting the start-up
threshold.
Cancel the adjustment of the start-up threshold using
WKHPHQXNH\¿JDQGHQWHUWKHUHTXLUHG
setting afresh as described in Chapter 5.3.4
8. Technical Data
Working Voltage 230 V 120 V
Permissible mains voltage 220 - 240 V 120 V
Mains frequency 50/60 Hz 60 Hz
Suction turbine power *) 1400 W 1400 W
max. connecting power *) 2000 W 360 W
Total connected power *) 3400 W 1800 W
Mains input fuse 2x 15 A (T)
max. connection pressure 8 bar
[116 psi]
min. connection pressure 4,5 bar
[65 psi]
/S$DWPD[YROXPHÀRZ 59 dB(A)
Number of suction hoses 2
9ROXPHÀRZPD[SHUVXFWLRQKRVH 3300 l/min
Vacuum pressure, max 20 kPa
[2,9 psi]
)LQHSDUWLFOH¿OWHU
Filter surface area ca. 0.8 m²
[ca. 1240 sq inch]
FIlterquality Class M according to EN60335-2-69
Fill volume, dust bag ca. 7,5 l
[2 US Gallonen]
Dimensions (height x width x depth) 595 x 225 x 565 mm
[23,4 x 8,8 x 22,2 inch]
Weight (empty) ca. 27 kg
[ca. 59,5 lbs]
6XFWLRQ¿WWLQJV
Internal 45 mm
[1,77 inch]
External 50 mm
[1,97 inch]
*) Working voltage power
**) Sound pressure levels according to EN ISO 11202
EN