23Installation – fixed system
7. Place the NC4 system on the adjuster pack
and attach the finger clamps with the fixing
screws.
8. Route the conduit through the machine. If
necessary, fit a cable gland where the
supplies exit the enclosure.
NOTE: The radius of the conduit bend
should be greater than 140 mm (5.51 in).
9. Route the cables to the electrical cabinet,
taking care to avoid situating them next to
sources of electrical noise, e.g. motors,
power cables, etc.
10. Route the air pipes to the air regulator.
11. Using the air regulator, purge the Ø4 mm air
pipe to remove any debris.
12. Remove the blanking plugs from the ends of
the air pipes. Connect the air pipes to the
outlet of the air filter / regulator unit using
the tee fittings and pneumatic adaptor
fittings as appropriate.
13. Fit conduit clamps to secure the conduit in
position on the table of the machine. This
will ensure that loads are not transferred to
the NC4 system when the machine
operates.
What to do next
After you have finished installing the NC4 fixed
system you should install the NCi-4 interface.
Conduit (to NC4)
Conduit clamps

Other manuals for Renishaw NC4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renishaw NC4 and is the answer not in the manual?

Renishaw NC4 Specifications

General IconGeneral
BrandRenishaw
ModelNC4
CategoryTools
LanguageEnglish

Related product manuals