9.5 Commissioning the control unit in control mode
Connect the control unit
Mount and connect the sensor
Automatic frequency search and controller mode
Initial commissioning using the example of a 50 Hz feeder:
Procedure Adjustment men
u and
parameters
Value Note
Adjust setpoint to zero Output \ Feeder 0% Avoid unintended and uncontrolled
feeder operation
Limiting output
frequency*
Limit values \ Min. freq.
Limit values \ Max. freq.
35 Hz
65 Hz
Limit the minimum and maximum output
frequency. Please note that the minimum
and maximum frequency limit values
exclude the multiples of the vibrating
frequency in the resonant frequency
search.
For safe operation, it is recommended to
limit the frequency range as much as
possible. In this example, the minimum
value is set to 35 Hz and the maximum
value to 65 Hz.
Switch Acc. controller
On
Feeder \ Acc. controller
This activates the amplitude control.
Switch Acc. controller
On
Feeder \ Auto freq.
This activates the frequency control.
Carefully increase the
setpoint
Output \ Feeder >0 %
As soon as the feeder's acceleration
generates a sufficiently strong sensor
signal, the frequency converter
automatically starts the automatic
frequency search and control.
Note! A setpoint set too low can lead to
incorrect results.
Caution! The increments of the setpoint
setting increase automatically when the
key is pressed for a longer time. Please
always press the button briefly for small
increments
The frequency converter automatically
saves the last frequency found.
Adjusting the vibration
amplitude
Output \ Feeder >0% As soon as the frequency converter
regulates stably at the resonant
frequency found, the desired vibration
amplitude can be set.
*only visible if the service menu is enabled.