RE 92004-01-S031/08.2015 | A4VG Series 40 Bosch Rexroth AG 25/40
Valves
7.3.1 Set pressure cut-off
This section describes how you check the pressure cut-off.
Risk of injury!
The following works on the variable pump are dangerous.
f Pay close attention to the safety instructions (see Chapter "2 General safety
instructions").
f While working with hazardous materials (for example, hydraulic fluids), always
wear safety gloves and safety glasses.
@
14
.)
:45
Fig. 14: Check pressure cut-off
To check the pressure cut-off:
1. Connect a pressure gauge (600 bar) to port MH.
2. Check pressure cut-off.
The exact settings are to be found in the data sheet in your order
documentation or in your specification.
WARNING!
Procedure