Bosch Rexroth Canada ıJune.2016 ı Revision 2.0
Error 67 - Joystick 2 Output Range Too Low. The difference between maximum and
minimum joystick nulling values for one of the six outputs was less than 5%.
Error 68 - Theoretical Maximum Conveyor RPM Too High. Based on the specified
application rate setpoints, and the maximum ground speed, the maximum
theoretical conveyor RPM required has been calculated to be more than twice the
actual conveyor capacity, which will lead to serious under-application problems. The
actual controller RPM setpoint will be clamped at this value to prevent the
controller from becoming unstable, and the conveyor should be re-calibrated to
determine the source of the problem.
Error 69 - Theoretical Maximum Pre-Wet Hz Too High. Based on the specified
application rate setpoints, and the maximum ground speed, the maximum
theoretical pre-wet pump flow required has been calculated to be more than twice
the actual pump capacity, which will lead to serious under-application problems.
The actual pump flow setpoint will be clamped at this value to prevent the
controller from becoming unstable, and the pre-wet pump should be re-calibrated to
determine the source of the problem.
Error 70 - Theoretical Maximum Anti-Ice Hz Too High. Based on the specified
application rate setpoints, and the maximum ground speed, the maximum
theoretical anti-ice pump flow required has been calculated to be more than twice
the actual pump capacity, which will lead to serious under-application problems.
The actual pump flow setpoint will be clamped at this value to prevent the
controller from becoming unstable, and the anti-ice pump should be re-calibrated to
determine the source of the problem.