22/29
Bosch Rexroth Canada ıJune.2016 ı Revision 2.0
13 Error Codes
The following error messages are user configurable, both timeouts and controller
actions.
The following Errors are warning messages, and not user configurable.
Error 20 - Output Non-Zero. This is a safety function to prevent the controller from
accidentally sending an unexpected output when the controller is turned on, or
when the user leaves programming mode and enters normal operation mode. The
outputs will be kept at zero until the error condition is removed. To recover, set the
application rates to zero or exit Blast mode.
Error 21 - Unload Not Allowed. An attempt was made to enter Unload mode while
the truck was moving, which is not allowed. The Unload command will be ignored in
this case.
Error 22 - BB3 System Error. This is an unrecoverable error in the RC controller. Try
rebooting the controller to see if it goes away, otherwise report the failure to Bosch
Rexroth. This error can also occur if an attempt is made to run a joystick without
having an RCE controller present.
Turn off blast/time too short
ERROR_DEICE_BLST_TOO_LONG
Turn off blast/time too short
Check cables, replace coil
Check cables, replace coil
Check cables, replace coil
Check cables, replace coil
Load material, check sensor
Load material, check sensor