Error 23 - This is a communication failure between the RC controller and the display.
It will show up in the logging history in the RC controller after the display is re-
connected.
Error 24 - RCE communication failure. This is a communication failure between the
RC controller and the RCE controller in a system with a joystick. It will automatically
shut down the joysticks. The status of this communication can also be monitored
using the display item called DIG which is available by double-tapping on the gear
icon while in normal operation mode. The item called DIG at the bottom right corner
of the display should normally be zero. It will be E0 if this error occurs.
Error 25 - Joystick 1 communication failure. This will shut down the joystick outputs,
and will show up as a 40 in the live DIG display item.
Error 26 - Joystick 2 communication failure. This will shut down the joystick outputs,
and will show up as a 80 in the live DIG display item.
Error 27 - No Chute Sensor. Chute sensor failure, most likely caused by cable break.
This will force the controller to stop.
Error 29 - No Ground Speed Simulation. This is just an information message to
indicate that ground speed simulation mode has been stopped.
Error 30 - Under-Application: Spinner. The spinner cannot meet the desired RPM
setpoint. This should not happen in manual mode, but could happen if the spinner is
in PPS mode and the ground speed is high.
Error 31 - Under-Application: Conveyor. The conveyor cannot meet the desired RPM
setpoint. Caused by too high application rate or too high ground speed or incorrect
calibration.
Error 32 - Under-Application: Pre-Wet. The pre-wet pump cannot meet the desired
flow setpoint. Caused by too high application rate or too high ground speed or
incorrect calibration.
Error 33 - Under-Application: Anti-Ice. The anti-ice pump cannot meet the desired
flow setpoint. Caused by too high application rate or too high ground speed or
incorrect calibration.
Error 34 - Over-Application: Conveyor. The solid application rate is above setpoint.
Most likely caused by a minimum null value for conveyor output that is too high, so
the conveyor never stops.
Error 35 - Over-Application: Pre-Wet. The pre-wet application rate is above setpoint.
Most likely caused by a minimum null value for the pre-wet pump output that is too
high, so the pump never stops.
Error 36 - Over-Application: Anti-Ice. The anti-ice application rate is above setpoint.
Most likely caused by a minimum null value for the anti-ice pump output that is too
high, so the pump never stops.