Error 37 - Calibration: Ground-Speed Pulses Too Low. Calculated pulses per km is
too low during calibration. Possibly caused by no sensor feedback, or try
recalibrating the ground speed sensor.
Error 38 - Spinner Maximum RPM Too Low. During auto nulling, the calculated
maximum RPM was too low, most likely caused by no sensor feedback.
Error 39 - Conveyor Maximum RPM Too Low. During auto nulling, the calculated
maximum RPM was too low, most likely caused by no sensor feedback.
Error 40 - Pre-Wet Maximum Hz Too Low. During auto nulling, the calculated
maximum Hz was too low, most likely caused by no sensor feedback.
Error 41 - Anti-Ice Maximum Hz Too Low. During auto nulling, the calculated
maximum Hz was too low, most likely caused by no sensor feedback.
Error 42 - Wrong Spinner Control Mode. An attempt was made to perform auto
nulling of a spinner while it was in manual.
Error 43 - Wrong Conveyor Control Mode. Not Used.
Error 44 - Wrong Pre-Wet Control Mode. An attempt was made to perform auto
nulling, or volume calibration, of a pre-wet pump while it was in manual.
Error 45 - Wrong Anti-Ice Control Mode. An attempt was made to perform auto
nulling, or volume calibration, of an anti-ice pump while it was in manual. This error
could also be caused by an I/O conflict between a cross conveyor mode and the
anti-ice pump output, in which case the anti-ice pump will be disabled.
Error 46 - Wrong Cross-Conveyor Mode. An attempt was made to go into Reverse
while this output was being used by a cross-conveyor mode. The Reverse command
will be ignored in this case. Could also be caused by attempting to use gm/sq.m.
mode while there was an I/O conflict with a Cross-Conveyor CA mode, in this case
gm/sq.m. mode will not be allowed. Could also be caused by attempting to use
closed-loop gate control while in Cross-Conveyor US mode or Liquid-Plus mode, in
which case the gate control will be forced into gate readback mode.
Error 47 - Wt. per Revolution Too Low. During conveyor weight calibration, the
calculated weight per revolution was too low, most likely caused by typing in zero
for the weight.
Error 48 - Wt. per Revolution Too High. During conveyor weight calibration, the
calculated weight per revolution was too high, most likely caused by no conveyor
sensor feedback.
Error 49 - Pre-Wet Pulses per Gallon Too Low. During calibration of pre-wet volume
output, the pulses/gal was too low, most likely caused by no flow sensor feedback.
Error 50 - Pre-Wet Pulses per Gallon Too Hi. During calibration of pre-wet volume
output, the pulses/gal was too high, most likely caused by typing in zero for the
volume.