2020 rf IDEAS Inc rfIDEAS Configuration Utility User Manual P a g e 27
Above image illustrates the various positions delimiter characters can be added to the card
data The numbered portions of the diagram are values FACID from the presented card
The letter portions of the character diagram are created by the user by modifying the pre
and post data delimiters in the utility and are keystroked with the FACID
Wiegand to Keystroke Data Format:
Strip Leading and Trailing Bit Count: By altering the numbers in the leading and trailing bit
count users have the option to strip and discard bits from the card data The leading and
trailing bit counts can be set to range from 0 to 15 for single configuration readers and 0 to
142 for dualfour configuration readers
Send FAC Facility Access Code: Enables FAC out when the card is presented
Send FAC as Hexadecimal Number: Sends FAC as a hex number the default is decimal
Send ID: Enables the reader to send the ID portion of the card data
Send ID as Hexadecimal Number: Sends ID in hex format
ID Field Bit Count: Sets the number of bits used for the ID range is 8 to 80
Fix length FAC ID Fields: Enables the FAC and ID to be set to a fixed length
FAC Digits: The FAC output is set to a length of digits between 1 and 32 Zeros are added to
the front of the FAC portion of the data to create a specific length
ID Digits: The ID output is set to a length of digits between 1 and 32 Zeros are added to the
front of the ID portion of the data to create a specific length
Advanced Settings:
Only Read Cards With This Bit Count: Only reads cards with the specified BIT Count range
adjustable 26 to 255
Display Hex in Lowercase: Displays the FACID in lowercase Hex format
Use Numeric Keypad: Defines which keypad the reader will use
AZERTY Keyboard Shift Lock: Displays the output as if it were being output from an
AZERTY keyboard