EasyManua.ls Logo

Ricoh Aficio 2035e - Cooling and Overheat Protection

Ricoh Aficio 2035e
869 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IMAGE FUSING AND PAPER EXIT
SM 6-99 B135/B138
Detailed
Descriptions
6.15.11 COOLING AND OVERHEAT PROTECTION
The fusing unit operates at temperatures lower than the previous model in order to
accommodate the new toner which has a lower melting temperature. In order to
further ensure cooler running temperatures for the fusing unit, two cooling fans
have been added.
The side cooling fan [A] and corner cooling fan [B] switch on when the temperature
of the fusing unit exceeds 150 °C and switch off when the main motor switches off.
If the hot roller temperature exceeds 230 °C for 5 seconds or more, the CPU cuts
off the power to the fusing lamp, and SC543 (Fusing Overheat Error) will be
displayed.
Even if the thermistor overheat protection fails, there is a thermostat in series with
the common ground line of the fusing lamp. If the temperature of the thermostat
reaches 210 °C, the thermostat opens, removing power from the fusing lamp. At
the same time, the copier stops operating. At this time, SC542 (Fusing
Temperature Warm-up Error) will be displayed.
B135D921.WMF
[A]
[B]

Table of Contents