FAX OPTION TYPE 2045
B563 4 SM
4. Attach the NCU unit [A] ( x 2).
NOTE: If a G3 Interface Unit type 2045 has to been installed, attach the
additional NCU boards to the NCU unit before attaching the NCU unit
to the machine. Refer to the Installation Procedure for the G3 Interface
Unit Type 2045.
5. Set up the jumper switches [B and C] on the NCU.
NOTE: European/Asian models only (non-U.S. version: B547-27)
Region/Country TB1 [B] TB2 [C]
Hong Kong OFF OFF
Hungary ON ON
Poland ON OFF
Czech Republic ON OFF
Israel ON ON
South Africa ON ON
Regions/countries where
the CTR21 standard is valid
ON ON
Other ON OFF
TB1 ON: Keep the jumper attached. OFF: Remove the jumper.
TB2 ON: Keep the jumper at ON. OFF: Move the jumper to OFF.
NOTE: You must change the country code in both system switch 0F and NCU
parameter CC (service function 08-0).
B653I902.WMF
B653I925.WMF
[A]
[B]