Page #73 background imageLoading...
Page #73 background image
73
9. Open the right front door and, on the Adjustment Settings for Skilled Operators
menu, press [0303: ITB Manual Lubrication].
10. Press [OK] and close the right door. Wait for the operation to finish.
This operation takes about five minutes during which time a message appears
on the control panel.
Note: Do not open the doors while it is in progress.
11. Open the left and right front doors.
12. Pull down both levers.
SEZ163
13. Reattach the cover with the two black screws.
CEZ119
14. Turn the machine off. (See p.14 "Power Off Sequence".)