2. Bit Switch Tables
Bit Switch 0
BIT FUNCTION
DATA
COMMENTS
0
Back to back con-
0: Disabled
To connect two machines directly without using a regular
figuration
1: Enabled
telephone company line, set this bit to 1, place a document in
one machine, and press Start on both machines. Do not dial a
number. After the test, reset this bit to 0.
1
Memory read/write 0: Accepted
When this bit is 0, a remote control system can read or write
request
1: Not accepted
RAM data such as TTl, RTI, and Bit Switches. The requester
must know the RAM addresses of this machine to make any
changes.
When this bit is 1, all requesters are locked out.
2
Action when other
0: The buzzer sounds 0: The buzzer warns that communication has failed. The user
end does not 1: DCN sent
must pick up the handset and press Stop.
respond to DIS 1: No user intervention is needed. Also, when in auto receive
after three tries
mode and if the speaker is switched off, the user will not be
able to talk to the sender before reception.
3
Running a
0: Press the program
Note that if this bit is 0, the user must press Stop immediately
Keystroke Program key to run the program. after programming a Keystroke Program, or the program will
1: Press the key then
start immediately. This is an Austrian PTT requirement.
the Start key to run the
program.
Continued on the next page
2-35