[Level]
Symptom Possible Cause/Required Action
movement of actuator at the
sensor while the motor rotates.
Defective IOB
1. Replace the transfer roller contact sensor.
2. Replace the transfer roller contact motor.
3. Replace the IOB.
490
[D]
High Voltage Power 1: High voltage output error
Error signal is detected 10
times consecutively.
One of the DC bias outputs for each PCU is shorted
or one of the transfer belt bias outputs for [Y], [M]
and [C].
Power leaking
Defective connection
Disconnected cable
Defective PCU
Defective High Voltage Power 1
1. Replace the High Voltage Power 1.
2. Reset the cables and components.
3. Replace the PCU.
491
[D]
High Voltage Power 2: High voltage output error
Error signal is detected for 10
times consecutively.
One of the separation bias output, development
bias output and transfer belt cleaning bias output is
shorted or one of the transfer belt bias output for [K]
and transfer roller bias output is shorted.
Power leaking
Defective connection
Defective PCU
Defective High Voltage Power 2
1. Replace the High Voltage Power 2.
2. Reset the cables and components.
3. Replace the PCU.
531
[D]
Paper feed / Fusing motor error
LOCK signal is not
detected for more than
Defective paper feed/ fusing motor
4. Troubleshooting