1105
[ToneCtlSave]
Saves the print gamma (adjusted with the Gamma Adj.) as the new Current Setting. Before
the machine stores the new “current setting”, it moves the data stored as the “current
setting” to the “previous setting” memory-storage location.
1106
[Toner Limit Value]
Adjusts the maximum toner amount for image development.
1106 001 TonerLimitValue *CTL [100 to 400 / 260 / 1%/step]
1108 [Ext. Toner Save]
1108 001 Mode 1: Text
DFU
1108 002 Mode 2: Text
1108 003 Mode 1: Image
1108 004 Mode 2: Image
1108 005 Mode 1: Line
1108 006 Mode 2: Line
1108 007 Mode 1: Paint
1108 008 Mode 2: Paint
Engine Service Mode
SP1-XXX (Feed)
1001
[Lead Edge Reg.] Leading Edge Registration
(Tray or By-pass, Paper Type, Process Speed)
Paper Type ->N: Plain paper 1, N2 or Normal 2: Plain paper 2, Thick2: Thick paper 2
(see the Specifications table for details on these paper weights)
Process Speed: LS: Low speed, RS: Regular speed
Service Mode Table
147