SC
[Level]
Symptom Possible Cause/Required Action
543
[A]
High temperature detection: Software
The thermistor detects 230°C
for 0.2 seconds.
Defective thermistor
Defective I/O board
Defective EGB
544
[A]
High temperature detection: Hard
The thermistor detects 250°C.
Defective thermistor
Defective I/O board
Defective EGB
Defective fusing unit, PSU, or EGB
1. Replace the fusing unit.
2. Replace the PSU.
545
[A]
Heating lamp error
The fusing lamp is full-
powered for 8 seconds after
the heating roller reaches the
print ready temperature.
Deformed thermistor
Thermistor coming off
Defective fusing lamp
547
[D]
Zero cross error
The zero cross signal is
detected three times even
though the heater relay is
off when turning on the
main power.
The zero cross signal is
not detected for three
seconds even though the
heater relay is on after
turning on the main
power or closing the front
door.
The detection error
occurs twice or more in
the ten zero cross signal
Defective fusing lamp relay
Defective fusing lamp relay circuit
Unstable power supply
1. Check the power supply source.
2. Replace the PSU.