[0 to 30 / 10 / 1deg /step]
1917 014 TC1: H: Temp. Dec. *EGB
Adjusts the temperature decrease for thick paper
1 at high temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 015 TC1: L: Temp. Inc. *EGB
Adjusts the temperature increase for thick paper 1
at low temperature.
[0 to 30 / 10 / 1deg /step]
1917 016 TC2: H: Temp. Dec. *EGB
Adjusts the temperature decrease for thick paper
2 at high temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 017 TC2: L: Temp. Inc. *EGB
Adjusts the temperature increase for thick paper 2
at low temperature.
[0 to 30 / 10 / 1deg /step]
1917 018 OHP: H: Temp. Dec. *EGB
Adjusts the temperature decrease for OHP at high
temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 019 OHP: L: Temp. Inc. *EGB
Adjusts the temperature increase for OHP at low
temperature.
[0 to 30 / 10 / 1deg /step]
1917 020 SP: H: Temp. Dec. *EGB
Adjusts the temperature decrease for special
paper at high temperature.
[-50 to 0 / 0 / 1 sec/step]
1917 021 SP: L: Temp. Inc. *EGB
Adjusts the temperature increase for special paper
at low temperature.
[0 to 30 / 10 / 1deg /step]
1917 022 ENV:H:Temp. Inc. *EGB
Adjusts the temperature increase for envelop at
high temperature.
[-50 to 0 / 0 / 1deg /step]
1917 023 ENV:L:Temp. Inc. *EGB
Adjusts the temperature increase for envelop at
low temperature.
[0 to 30 / 7 / 1deg /step]
1917 024 GL:H:Temp. Inc. *EGB
Adjusts the temperature increase for glossary
paper at high temperature.