Paper Side: 1st or 2nd
2477 013 RS: 1st: T.Roll2 *EGB [0 to 100 / 15.0 / 0.1 -µA/step]
2477 014 RS: 1st:Separa. *EGB [0 to 4 / 2 / 0.1 -kV/step]
2477 021 RS: 2nd: T.Roll2 *EGB [0 to 100 / 15.0 / 0.1 -µA/step]
2477 022 RS: 2nd: Separa. *EGB [0 to 4 / 2 / 0.1 -kV/step]
2478
[Glossy2:[FC]] Transfer roller current and discharge plate voltage for the trailing edge
area of glossy paper 2 in color mode
Paper Side: 1st or 2nd
2478 013 LS: 1st: T.Roll2 *EGB [0 to 100 / 10.0 / 0.1 -µA /step]
2478 014 LS: 1st: Separa. *EGB [0 to 4 / 2 / 0.1 -kV/step]
2478 021 LS: 2nd: T.Roll2 *EGB [0 to 100 / 10.0 / 0.1 -µA/step]
2478 022 LS: 2nd: Separa. *EGB [0 to 4 / 2 / 0.1 -kV/step]
2481
[Spec1:[K]:TE] Transfer roller current and discharge plate voltage correction for the
leading edge area of special paper 1 in B/W mode
Paper Side: 1st or 2nd
2481 007 RS: 1st: T.Roll2 *EGB [0 to 400 / 100 / 5%/step]
The value displayed on the LCD is different from
these SP's values. For example, "20%" on the LCD
actually means 100%.
2481 012 RS: 2nd: T.Roll2 *EGB
2483
[Spec1:[K]:LE] Transfer roller current and discharge plate voltage correction for the
trailing edge area of special paper 1 in B/W mode
Paper Side: 1st or 2nd
2483 007 LS: 1st: T.Roll2 *EGB [0 to 400 / 100 / 5%/step]
The value displayed on the LCD is different from
these SP's values. For example, "20%" on the LCD
actually means 100%.
2483 012 LS: 2nd: T.Roll2 *EGB
2486
[Spec1:[FC]:TE] Transfer roller current and discharge plate voltage correction for the
leading edge area of special paper 1 in color mode
Service Mode Table
195