5924 [SDK Apli Display] SDK Application Display
5924 001 SDK Appli Display *CTL
Enables or disables the LCD display of the SDK
application.
[0 or 1 / 0 / 1/step]
0: Not display, 1: Display
5930 [Meter Click Ch.] Meter Click Charge
5930 001 Meter Click Ch. *EGB
Enables or disables the Meter Charge mode. When
enabling the Meter Charge mode, the “Counter”
menu is added to the user menu.
[0 or 1 / 0 / -]
0: OFF, 1: ON
5930 010 PCU *EGB
Displays or does not display the end display for the
PCU. This SP is activated only when the
SP5930-001 is set to "1".
[0 or 1 / 0 / -]
0: OFF, 1: ON
5930 014 Mid Trans Unit *EGB
Displays or does not display the end display for the
transfer belt unit. This SP is activated only when the
SP5930-001 is set to "1".
[0 or 1 / 0 / -]
0: OFF, 1: ON
5930 016 Fusing Unit. *EGB
Displays or does not display the end display for the
fusing unit. This SP is activated only when the
SP5930-001 is set to "1".
[0 or 1 / 0 / -]
0: OFF, 1: ON
5990 [SP Print Mode]
5990 001 All (Data List) Does SP5-990-002, 004, 005, 006, and 007.
5990 002 SP (Mode Data List) Prints an SMC report on all SP modes.
5990 004 Logging Data Prints an SMC report on the SPs that save logs.
Service Mode Table
279