SC
[Level]
Symptom Possible Cause/Required Action
turns on while the polygon
motor is rotating normally.
230
[C]
FGATE: On error [K]
The PFGATE ON signal does
not assert within 5 seconds
after processing the image in
normal job or MUSIC for [K]
starts.
Defective connection between the controller board
and EGB
Defective cable between the EGB and LDB
1. Check the connectors.
2. Replace the LDB.
3. Replace the EGB.
231
[C]
FGATE: Off error [K]
The PFGATE ON signal
still asserts within 5
seconds after processing
the image in normal job
or MUSIC for [K] ends.
The PFGATE ON signal
still asserts when the next
job starts.
Defective connection between the controller board
and EGB
Defective cable between the EGB and LDB
1. Check the connectors.
2. Replace the LDB.
3. Replace the EGB.
232
[C]
FGATE: On error [Y]
The PFGATE register of GAVD
does not assert within 5
seconds after processing the
image in normal job or MUSIC
for [Y] started.
Same as SC 230
233
[C]
FGATE: Off error [Y]
The PFGATE ON signal
still asserts within 5
seconds after processing
the image in normal job
or MUSIC for [K] ends.
The PFGATE ON signal
still asserts when the next
job starts.
Same as SC 231