Image Correction
J012/J013/J014 4-52 SM
7. Fold the printed sheet in half lengthwise as shown.
8. Hold the corner of the folded paper in front of a light and look at the cross-pattern
overlapping the single vertical line below.
9. Determine the 1st adjustment for the Read Direction.
The adjustment value in the Read Direction is the difference between the single
vertical line and cross vertical line.
If the difference is one calibration mark on the "+" side, for example, the adjustment
is +1.0.
10. Unfold the paper then fold the sheet in half widthwise.
11. Determine the 2nd adjustment for the Feed Direction.
The value read after folding the sheet widthwise is the adjustment value for the
Feed Direction.
12. ['] or [(] > "Adjust" > [Yes]> "Tray1"
13. ['] or [(] > Select the tray ("Tray1", Tray2", "Bypass")> [Yes]
14. ['] or [(] > Select item to adjust ("Plain( ) ", "Plain(Y) ", "Glossy", "Transparency).
The "Plain", "Glossy", and "Transparency" settings are provided because the
sensor timing for each is different.
Select "Plain( )" to do the adjustment in the Read Direction (horizontal).
Select "Plain (Y) to do an adjustment for the Feed Direction (vertical).