To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
20140262
GB
Technical description of the burner
4.1 Burner designation
4.2 Models available
Tab. A
4.3 Burner categories - Countries of destination
Tab. B
NOTE:
only for Switzerland: Swiss regulations, those of the SVGW for
the use of gas, Canton and local regulations, as well as Fire Ser-
vices regulations (VKF).
4 Technical description of the burner
Designation Combustion head Voltage Code
BS1F TC 1/230/50 3761171
BS2F TC 1/230/50 3761271
BS3F TC 1/230/50 3761371
BS4F TC 1/230/50 3761471
Range:
Size
Fuel: Natural gas
LPG
Variations:
Electrical power supply 1/230/50
1/220/60
B S 1 1/230/50
BASIC DESIGNATION
EXTENDED DESIGNATION
1/230V/50Hz
1/220V/60Hz
F Light industrial process
M Progressive two-stage or modulating
D Two-stage
S
SP
Head:
TC Standard head
TL Extended head
of the system:
Standard Emission
Low NOx
R
B
TCF
Country of destination Gas category
SE - FI - AT - GR - DK - ES - GB - IT - IE - PT - IS - CH - NO I
2H
DE I
2ELL
NL
I
2E
- I
2
(43.46 - 45.3 MJ/m
3
(0°C))
FR I
2Er
BE I
2E(R)B
LU - PL I
2E

Table of Contents