4)RUGLႇHUHQWIXQFWLRQVSXPSV
P_c N
9
21
PUMP_c
CONTROL SIGNAL
OUTPUT
(For zone 2 pump)
P_o N
10
PUMP_o
CONTROL SIGNAL
OUTPUT
(For zone 1 pump or
outside circulating pump)
22
P_s
N
PUMP_s
CONTROL SIGNAL
OUTPUT
(For solar pump)
11
23
P_d
N
12
PUMP_d
CONTROL SIGNAL
OUTPUT
(For DHW tank
circulating pump)
24
Voltage 220-240VAC
Maximum running current (A) 0,2
Wiring size (mm²) 0,75
Control port signal type Type 2
Procedure
Connect the cable to the appropriate terminals as shown in the picture.
Fix the cable reliably.
5. For tank booster heater
N
13
16
TBH
TANK BOOST HEATER
CONTROL SIGNAL OUTPUT
Voltage 220-240VAC
Maximum running current (A) 0,2
Wiring size (mm²) 0,75
Control port signal type Type 2
Connection of the booster heater cable depends on the application. Only when the domestic hot water tank is installed will this wiring be needed.
7KHXQLWRQO\VHQGVDWXUQRQRႇVLJQDOWRWKHERRVWHUKHDWHU$QDGGLWLRQDOFLUFXLWEUHDNHULVQHHGHGDQGDGHGLFDWHGWHUPLQDOLVQHHGHGWRVXSSO\
power to the booster heater.
6HHDOVR7\SLFDODSSOLFDWLRQH[DPSOHVDQG)LHOGVHWWLQJV'+:FRQWURO´IRUPRUHLQIRUPDWLRQ
Procedure
Connect the cable to the appropriate terminals as shown in the picture.
Fix the cable with cable ties to the cable tie mountings to ensure stress relief.
6. For external backup heater kit (optional)
IBH1 N
14
16
IBH1
CONTROL SIGNAL
OUTPUT
Voltage 220-240VAC
Maximum running current (A) 0,2
Wiring size (mm²) 0,75
Control port signal type Type 2
7. For antifreeze e-heating tape (external)
HT N
25
29
Heating
CONTROL SIGNAL
OUTPUT
Voltage 220-240VAC
Maximum running current (A) 0,2
Wiring size (mm²) 0,75
Control port signal type Type 2
8. For unit running state output
R2 R1
26
30
Runnig state
CONTROL SIGNAL
OUTPUT
Voltage 220-240VAC
Maximum running current (A) 0,2
Wiring size (mm²) 0,75
Control port signal type Type 2