RIGOL
© 2006 RIGOL Technologies, Inc
User’s Guide for DG2000 Series
5-5
Carrier Waveforms Sine, Square, Ramp, Arb
Source Internal/ External
Modulating Waveforms 50% duty cycle square (2mHz to 100kHz)
PWM Modulation
Carrier Waveforms Pulse
Source Internal/ External
Modulating Waveforms Sine, Square, Ramp, Noise, Arb (2mHz to 20kHz)
Deviation pulse width: 0% to 100%
Sweep
Carrier Waveforms Sine, Square, Ramp, Arb
Type Linear or Logarithmic
Sweep Time 1 ms to 500 s ± 0.1%
Source Internal/External/Manual
Burst
Waveforms Sine, Square, Ramp, Pulse, Noise, Arb
Types Count (1 to 1,000,000 periods), infinite, gated
Start Phase -360° to +360°
Internal Period 1 μs – 500 s ± 1%
Gate Source External Trigger
Trigger Source Internal/External/Manual
Rear Panel Connector
External AM
Modulation
± 5 Vpk = 100% modulation
5kΩ input impedance
Input/Output
Frequency Range
10MHz ± 500Hz
Input/Output Voltage
Range
80mVpp~10Vpp/0dBm (typical)
Input/Output
Impedance
2kΩ/50Ω (typical), AC coupled
Time <1s
External Trigger TTL-compatible
Trigger Input
Input Level TTL-compatible
Slope Rising or falling (selectable)
Pulse Width > 100 ns
Input Impedance > 10 kΩ, DC coupled