RIGOL Programming Introduction
Programming Guide for DS1000CA Series
3. :TRIGger:VIDEO:STANdard
Command Format:
:TRIGger:VIDEO:STANdard {NTSC|PALSecam}
:TRIGger:VIDEO:STANdard?
Function Explanation:
The commands are used to set and query the video type as “NTSC”or
“PALSecam".
Returned Format:
Query returns “NTSC” or “PAL/SECAM”.
Example:
:TRIG:VIDEO:STAN PALS Set the video type as “PALSecam"
:TRIG:VIDEO:STAN? Query returns “PAL/SECAM”
4. :TRIGger:VIDEO:LINE
Command Format:
:TRIGger:VIDEO:LINE <value>
:TRIGger:VIDEO:LINE?
Function Explanation:
The commands are used to set and query the number of synchronous
appointed lines.
In NTSC standard, the range of <value> is 1~525;
In PALSecam standard, the range of <value> is 1~625.
Returned Format:
Query returns the set value of lines.
Example:
:TRIG:VIDEO:LINE 25 Set number of synchronous appointed lines as 25
:TRIG:VIDEO:LINE? Query returns 25