EasyManua.ls Logo

Rigol DS1000CA Series - Page 51

Rigol DS1000CA Series
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming Introduction RIGOL
Programming Guide for DS1000CA Series
2-39
11. :TRIGger:ALTernation:VIDEO:LINE
Command Format:
:TRIGger:ALTernation:VIDEO:LINE <value>
:TRIGger:ALTernation:VIDEO:LINE?
Function Explanation:
The commands are used to set and query the number of appointed
synchronous lines.
In NTSC standard, the range of <value> is 1~525;
In PALSecam standard, the range of <value> is 1~ 625.
Returned Format:
Query returns the set value of <value>.
Example:
:TRIG:ALT:VIDEO:LINE 100 Set the number as 100
:TRIG:ALT:VIDEO:LINE? Query returns 100
12. :TRIGger:ALTernation:SLOPe:WINDow
Command Format:
:TRIGger:ALTernation:SLOPe:WINDow <count>
:TRIGger:ALTernation:SLOPe:WINDow?
Function Explanation:
The commands are used to set and query trigger level of the vertical window.
The options of <count> are “PA, “PB” or “PAB” when slope condition is
“+GREaterthan”, “+LESSthan” or “+EQUal”;
The options of <count> are NA”, NB” or NAB” when slope condition is
-GREaterthan”, -LESSthan” or -EQUal”.
Returned Format:
Query returns “P_WIN_A, “P_WIN_B”, P_WIN_AB”, “N_WIN_A, “N_WIN_B
or “N_WIN_AB”.
Example:

Other manuals for Rigol DS1000CA Series

Related product manuals