Programming Introduction RIGOL
Programming Guide for DS1000CA Series
2-49
1. :CHANnel<n>:BWLimit
Command Format:
:CHANnel<n>:BWLimit {ON|OFF}
:CHANnel<n>:BWLimit?
Function Explanation:
The commands are used to set and query the bandwidth limit “ON” or “OFF”.
<n> is 1 or 2.
Returned Format:
Query returns “ON” or “OFF”.
Example:
:CHAN2:BWL OFF Set Channel 2 bandwidth limit “OFF”
:CHAN2:BWL? Query returns “OFF”
2. :CHANnel<n>:COUPling
Command Format:
:CHANnel<n>:COUPling {DC|AC|GND}
:CHANnel<n>:COUPling?
Function Explanation:
The commands are used to set and query the coupling as “DC”, AC” or “GND”.
<n> is 1 or 2.
Returned Format:
Query returns “DC”, AC” or “GND”.
Example:
:CHAN2:COUP DC Set the coupling type of Channel 2 as DC
:CHAN2:COUP? Query returns “DC”
3. :CHANnel<n>:DISPlay
Command Format: