Function Explanation:
This command is used to query the overshoot value of the waveform.
Generally, signal overshoot is in terms of percentage, and the transformational
relation of the overshoot value and percentage is: overshoot*100. For
example: overshoot = 8.00e3 mens this signal overshoot is 0.8%.
The options of <source> are CHANnel1 or CHANnel2.
Returned Format:
Such as 8.00e-03.
11. :MEASure:PREShoot?
Command Format:
:MEASure:PREShoot? [<source>]
Function Explanation:
This command is used to query the preshoot value of the waveform. The
options of <source> are CHANnel1 or CHANnel2.
Returned Format:
Such as 8.00e-03.
12. :MEASure:FREQuency?
Command Format:
:MEASure:FREQuency? [<source>]
Function Explanation:
This command is used to query the waveform frequency. The options of
<source> are CHANnel1 or CHANnel2.
Returned Format:
Such as 1.00e+03, the unit is Hz.
13. :MEASure:RISetime?