RIGOL Chapter 2 Command System
2-118 DS1000Z Programming Guide
:TRIGger:SHOLd:STIMe
Syntax :TRIGger:SHOLd:STIMe <NR3>
:TRIGger:SHOLd:STIMe?
Description
Set or query the setup time in setup/hold trigger. The default unit is s.
Parameter
Name
Type
Range
Default
<NR3> Real 8ns to 1s 1μs
Explanation This command is only available when the setup type (refer to :TRIGger:SHOLd:TYPe) is
SETup or SETHOLd.
Return
Format
The query returns the setup time in scientific notation.
Example
:TRIGger:SHOLd:STIMe 0.002 /*Set the setup time to 2ms*/
:TRIGger:SHOLd:STIMe? /*The query returns 2.000000e-03*/
Related
Commands
:TRIGger:SHOLd:TYPe
:TRIGger:SHOLd:HTIMe
:TRIGger:SHOLd:HTIMe
Syntax :TRIGger:SHOLd:HTIMe <NR3>
:TRIGger:SHOLd:HTIMe?
Description
Set or query the hold time in setup/hold trigger. The default unit is s.
Parameter
Name Type Range Default
<NR3>
Real
8ns to 1s
1μs
Explanation This command is only available when the setup type (refer to :TRIGger:SHOLd:TYPe) is
HOLd or SETHOLd.
Return
Format
The query returns the hold time in scientific notation.
Example
:TRIGger:SHOLd:HTIMe 0.002 /*Set the hold time to 2ms*/
:TRIGger:SHOLd:HTIMe? /*The query returns 2.000000e-03*/
Related
Commands
:TRIGger:SHOLd:TYPe
:TRIGger:SHOLd:STIMe