Upon selecting the “Fault History” function the scan tool will display each
historic fault that the ECM has logged followed by the time of occurrence. Aer
all historic faults are displayed the scan tool will prompt you to either review the
faults or exit to the main ECM system menu.
Erase Fault History
is function clears the Fault History memory. All historic faults along with their
occurrence times will be erased.
Run History
e electronic control module has the ability to record the number of hours an
engine has been operated within a predetermined set of RPM ranges. is infor-
mation provides a technician with a prole of how the engine has been operated.
To view Run History information select the “Run History” menu option then
press YES. e scanner will display the number of hours the engine has oper-
ated in various RPM ranges as well as the total number of hours the engine has
logged. Use the and keys to scroll through the available data. Aer view-
ing the Run History data press the NO key to return to the main ECM system
menu.