2005 - Up 75 / 90hp EFI 4-Cycle
Page 49
Upon selecting the “Fault History” function the scan tool will display each
historic fault that the ECM has logged followed by the time of occurrence. Aer
all historic faults are displayed the scan tool will prompt you to either review the
faults or exit to the main ECM system menu.
Erase Fault History
is function clears the Fault History memory. All historic faults along with their
occurrence times will be erased.
Run History
e electronic control module has the ability to record the number of hours an
engine has been operated within a predetermined set of RPM ranges. is infor-
mation provides a technician with a prole of how the engine has been operated.
To view Run History information select the “Run History” menu option then
press YES. e scanner will display the number of hours the engine has oper-
ated in various RPM ranges as well as the total number of hours the engine has
logged. Use the ▲ and ▼ keys to scroll through the available data. Aer view-
ing the Run History data press the NO key to return to the main ECM system
menu.