KBD Series Manual
Temperatures Available with a Controller
The water heater can deliver water at only one temperature seng at a me. The available temperatures are
provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” buon
for 5 seconds while the water heater is OFF.
These temperatures are suggesƟons only:
* Temperature sengs from 125-140 °F (52-60 °C) are available by seng SW6 in DIPSW 1 to ON. These
models have a default maximum temperature of 120° F (49° C) and an opon (SW6) to increase the
maximum temperature to 140 °F (60 °C).
DO NOT adjust the other switches unless specifically instructed to do so.
WARNING
x Kitchen 120 °F (49° C)
x Shower 98 - 110 °F (37 - 43 °C)
x Bath Fill 102 - 110 °F (39 - 43 °C)
Temperature Seƫngs Available
Fahrenheit °F 98 100 102 104 106 108 110 115 120
125
*
130
*
135
*
140
*
150
**
160
**
185
**
Celsius °C 37 38 39 40 41 42 43 46 49 52 54 57 60 66 71 85
** These sengs require the MCC-91-2 controller. When the MCC-91-2 controller is connected, these higher
temperatures are available on all controller models in the system. Use of an MCC-91-2 controller in a
residenal dwelling will reduce the warranty coverage to that of a commercial warranty applicaon.
Alternate Temperature Sengs
A different range of temperature sengs is available by seng SW2 and SW3 in the DIPSW 2 to ON. The table
below shows the sengs available with the MC-91-2 and MCC-91-2 controller.
Alternate Temperature Seƫngs Available
Fahrenheit °F 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185
Celsius °C 43 46 49 52 54 57 60 63 66 68 71 74 77 79 82 85
MC-91-2
MCC
-91
-2
MC-9
1-1, MCC-91-1, MC-100V-1, and BC-100V-1 controllers are not compa
ble with
Alternate
Temperature Sengs. Alternate Temperature Sengs are for commer
cial
applicaons o
nly.
DO NOT use the MC-91-1, MCC-91-1, MC-100V-1, or BC-100V-1 controllers when SW2
and SW3 in DIPSW 2 are in the ON posion.
WARNING